воскресенье, 22 октября 2017 г.

Мониторинг дисков используя megacli

Смотрим какие у нас есть диски.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
root@il-nv-s06:~# lshw -c disk
  *-disk:0
       description: SCSI Disk
       product: SMC2108
       vendor: SMC
       physical id: 2.0.0
       bus info: scsi@0:2.0.0
       logical name: /dev/sda
       version: 2.90
       serial: 0074df64060b7e521510538600800403
       size: 2791GiB (2996GB)
       capabilities: gpt-1.00 partitioned partitioned:gpt
       configuration: ansiversion=5 guid=02712922-3f89-4077-8a1b-2ed197f3c54c
  *-disk:1
       description: SCSI Disk
       product: SMC2108
       vendor: SMC
       physical id: 2.1.0
       bus info: scsi@0:2.1.0
       logical name: /dev/sdb
       version: 2.90
       serial: 00405d940d100d0a1810538600800403
       size: 54GiB (58GB)
       capabilities: gpt-1.00 partitioned partitioned:gpt
       configuration: ansiversion=5 guid=992168b5-1ecd-4e43-ab0f-f2e0b945ab27
  *-disk:2
       description: SCSI Disk
       product: SMC2108
       vendor: SMC
       physical id: 2.2.0
       bus info: scsi@0:2.2.0
       logical name: /dev/sdc
       version: 2.90
       serial: 00074cce4a116a071810538600800403
       size: 7446GiB (7995GB)
       capabilities: gpt-1.00 partitioned partitioned:gpt
       configuration: ansiversion=5 guid=92c542ab-7199-4525-89e3-057744b8397d
SMC2108 — означает, что у нас Supermicro MC2108 контроллер. Так же можно убедиться, что у нас Megaraid контроллер используя эту команду.
1
2
root@il-nv-s06:~# cat /proc/devices | grep mega
250 megaraid_sas_ioctl
Как видим, у нас LSI SAS MegaRAID контроллер, диски которого можно мониторить используя smartctl или же используя специализированную утилиту megacli. Для начала присмотримся к megacli. В стандартных репозиториях ее нет, но можно скачать с официального сайта и собрать с исходников. Но я рекомендую использовать специальный репозиторий (за который хочу сказать ОГРОМНОЕ спасибо) в котором есть почти весь набор специализированных утилиты под любой тип аппаратных рейдов.
1
2
3
4
root@il-nv-s06:~# echo 'deb http://hwraid.le-vert.net/ubuntu precise main' > /etc/apt/sources.list.d/raid.list
root@il-nv-s06:~# wget -O - http://hwraid.le-vert.net/debian/hwraid.le-vert.net.gpg.key | sudo apt-key add -
root@il-nv-s06:~# apt-get update
root@il-nv-s06:~# apt-get install megacli
Перечень всех доступных в репозитории утилит наведен здесь
Проверяем на ошибки физический диск megaraid используя megacli.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
root@il-nv-s06:~# megacli -pdinfo -physdrv [4:0] -aALL
 
Enclosure Device ID: 4
Slot Number: 0
Drive's position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 0
WWN: 5000C5002130CD08
Sequence Number: 2
Media Error Count: 38
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
 
Raw Size: 931.512 GB [0x74706db0 Sectors]
Non Coerced Size: 931.012 GB [0x74606db0 Sectors]
Coerced Size: 930.390 GB [0x744c8000 Sectors]
Sector Size:  0
Firmware state: Online, Spun Up
Device Firmware Level: 0005
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c5002130cd09
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST31000424SS    00059WK1D042
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive:  Not Certified
Drive Temperature :29C (84.20 F)
PI Eligibility:  No
Drive is formatted for PI information:  No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Как видим, на первом физическом диске есть «Media Error Count: 38». Это означает, что запасные(зарезервированные) сектора для remap(замены) битых секторов диска — закончились. И нужно проводить замену диска.
Так же нужно мониторить следующие параметры используя команду:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
root@il-nv-s06:~# megacli -LdPdInfo -aALL | grep -E "(Id|State |Bad Blocks|Firmware state|Error Count|Predictive Failure Count)"
# Первый виртуальный диск - он же /dev/sda
Virtual Drive: 0 (Target Id: 0)
# Статус RAID-a (Degraded - если проблема с одним из дисков; Optimal - нормальный статус)
State               : Degraded
# Наличие бедблоков на виртуальном диске
Bad Blocks Exist: No
# ID физического диска
Device Id: 14
# Количество ошибок, которые нет возможности исправить - самый важный компонент
Media Error Count: 0
# Количество иных ошибок не связанных с бедблоками
Other Error Count: 0
# Определение количества возможных ошибок
Predictive Failure Count: 0
# Статус физического диска (Rebuild - добавляется в RAID; Online - в RAID-e)
# Также есть "Failed", "Online, Spun Up", "Online, Spun Down", "Unconfigured(bad)", "Unconfigured(good), Spun down","Hotspare, Spun down", "Hotspare, Spun up" or "not Online".
Firmware state: Rebuild
Device Id: 1
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Firmware state: Online, Spun Up
Device Id: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Firmware state: Online, Spun Up
Device Id: 3
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Firmware state: Online, Spun Up
Virtual Drive: 1 (Target Id: 1)
State               : Optimal
Bad Blocks Exist: No
Device Id: 13
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Firmware state: Online, Spun Up
Media Type: Solid State Device
Device Id: 12
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Firmware state: Online, Spun Up
Media Type: Solid State Device
Теперь напишем маленький скрипт для мониторинга всех нужных параметров включая BBU.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
root@il-nv-s06:~# cat megaraid.sh
#!/bin/bash
#Вся информация по физическим и логическим дискам
VD_PDID_ERRORS=`megacli -ldpdinfo -aALL | grep -E "(Id|State  |Media Error|Firmware state)"`
#Вся информация по батарее
BBU_OUT=`megacli -AdpBbuCmd -aAll | grep -E "(Full Charge|^Max Error|Battery State)"`
while read line
do
        #Ловим название (ID) логического диска
        VD=`echo ${line} | grep -Eo "Virtual Drive: [0-9]"`
        #Ловим название (ID) физического диска
        PD_ID=`echo ${line} | grep -E "Device Id:"`
        #Ловим важные ошибки физических дисков
        PD_ERRORS=`echo ${line} | grep -E "(Media Error)"`
        #Ловим статус рейда
        RAID_STAT=`echo ${line} | grep -E "State"`
        #Ловим статус прошивки
        PD_FIRMWARE=`echo ${line} | grep -E "Firmware"`
        if [ -n "${VD}" ]
        then
                DRIVE="${VD} ==> "
        elif [ -n "${RAID_STAT}" ]
        then
                VD_RAID_STAT=`echo "${RAID_STAT}" | awk '{print $3}'`
                VD_RAID="${DRIVE}${RAID_STAT} ==> "
                #Если статус рейда отличается от нормального - число ошибок растет
                if [ ${VD_RAID_STAT} != 'Optimal'  ]
                then
                        #echo "Raid with problem"
                        VDRIVE_WITH_FAIL="${VD_RAID}
 ${VDRIVE_WITH_FAIL}"
                        let "ERROR_COUNT += 1"
                fi
        elif [ -n "${PD_ID}" ]
        then
                PD_DRIVE="${DRIVE}${PD_ID} ==> "
        elif [ -n "${PD_ERRORS}" ]
        then
                #Если есть ошибка - ловим их количество
                PD_ERR=${PD_DRIVE}${PD_ERRORS}
                let "ERROR_COUNT +=`echo ${PD_ERRORS} | awk '{print $4}'`"
                TRAP=`echo ${PD_ERRORS} | awk '{print $4}'`
                if [ ${TRAP} -ne 0 ]
                then
                        DISK_WITH_FAIL="${PD_ERR}
 ${DISK_WITH_FAIL}"
                fi
        elif [ -n "${PD_FIRMWARE}" ]
        then
                #Проверяем или прошивка в порядке, если нет - число ошибок растет
                PD_FIRM_STATUS=`echo "${PD_FIRMWARE}" | cut --delimiter=":" -f2 | sed 's/ //g'`
                PD_FIRM=${PD_DRIVE}${PD_FIRMWARE}
                if [ ${PD_FIRM_STATUS} != "Online,SpunUp" ]
                then
                        #echo "PD firmware with problem"
                        PDFIRM_WITH_FAIL="${PD_FIRM}
 ${PDFIRM_WITH_FAIL}"
                        let "ERROR_COUNT += 1"
                fi
        fi
done <<< "${VD_PDID_ERRORS}"
 
while read bbu_log
do
        BBU_STATE=`echo ${bbu_log} | grep -E "Battery State"`
        BBU_ERROR=`echo ${bbu_log} | grep -E "Max Error"`
        BBU_CHARGE=`echo ${bbu_log} | grep -E "Full Charge"`
        if [ -n "${BBU_STATE}" ]
        then
                BBU_ST=`echo "${BBU_STATE}" | awk '{print $3}'`
                #echo ${BBU_ST}
                if [ ${BBU_ST} = "Unknown" ]
                then
                        #echo "Battery status is Unknown"
                        let "ERROR_COUNT = 250"
                        BBUSU_WITH_FAIL="${BBU_STATE}"
                elif [ ${BBU_ST} != "Optimal"  ]
                then
                        #echo "Battery STATUS is BAD"
                        BBUS_WITH_FAIL="${BBU_STATE}"
                        let "ERROR_COUNT = 251"
 
                fi
        elif [ -n "${BBU_ERROR}" ]
        then
                BBU_ER=`echo ${BBU_ERROR} | awk '{print $4}'`
                #echo ${BBU_ER}
                if [ "${BBU_ER}" -ge "11" ]
                then
                        #echo "Battery has ERRORS"
                        BBUE_WITH_FAIL="${BBU_ERROR}"
                        let "ERROR_COUNT = 252"
                fi
        elif [ -n "${BBU_CHARGE}" ]
        then
                BBU_CHAR=`echo ${BBU_CHARGE} | awk '{print $4}'`
                #echo ${BBU_CHAR}
                if [ "${BBU_CHAR}" -lt "675" ]
                then
                        #echo "Battery has low CHARGE"
                        BBUC_WITH_FAIL="${BBU_CHARGE}"
                        let "ERROR_COUNT = 253"
                fi
        fi
done <<< "${BBU_OUT}"
 
if [[ -n $1 ]] && [ $1 == 'log' ]
then
        echo "${VDRIVE_WITH_FAIL}
 ${DISK_WITH_FAIL}
 ${PDFIRM_WITH_FAIL}
 ${BBUS_WITH_FAIL}
 ${BBUSU_WITH_FAIL}
 ${BBUE_WITH_FAIL}
 ${BBUC_WITH_FAIL} "
else
        echo $ERROR_COUNT
fi
exit 0
Данный скрипт проверяет все диски на наличие проблем с прошивкой,состояние рейда,ошибки физических дисков и состояние батареи. Если есть проблема с батареей — код выхода скрипта будет больше 250, если проблемы с остальными устройствами, то будет выведено только количество ошибок. Скрипт запускается без аргументов. Если добавить аргумент log, будет выведено текст с указанием проблемного элемента. Проверяем работу скрипта:
1
2
3
4
root@il-nv-s06:~# ./megaraid.sh
252
root@il-nv-s06:~# ./megaraid.sh log
Max Error = 14 %
Как видим у нас проблема с батареей (BBU) и ее нужно заменить.
По роботе с magacli есть целая книга-руководство.
Из полезных команд:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
# Просмотр журнала событий BBU, где можно найти информацию по проверкам и автоисправлению  битых секторов
megacli -fwtermlog -dsply -aall > /tmp/ttylog.txt
# Полная информация о всех адаптеров контроллера
megacli -AdpAllInfo -aALL
# Полная информация о настройках и дисках
megacli -CfgDsply -aALL
# Информация о последних событиях, где можно найти информацию о сбои в работе дисков
megacli -AdpEventLog -GetLatest 4000 -f events.log -aALL
megacli -AdpEventLog -GetEvents -f events.log -aALL
# Информация о всех доступных корпусах контроллера
megacli -EncInfo -aALL
# Список всех логических дисков и типе RAID-а в котором они собраны
megacli -LDInfo -Lall -aALL
# Список всех физических дисков
megacli -PDList -aALL
# Информация о конкретном физическом диске
# Типовая комманда megacli -pdinfo -physdrv [E1:S2] -aALL
# E1 - Enclosure Device ID: 1, S2 - Slot Number: 2
# To get it need to run - megacli -LdPdInfo -aALL | grep -E "ID|Slot"
megacli -pdinfo -physdrv [4:2] -aALL
# Засветить диск
#Start blinking
megacli -PdLocate -start -physdrv\[4:3\]  -aALL
megacli -PdLocate -start -physdrv\[4:2\]  -aALL
megacli -PdLocate -start -physdrv\[4:1\]  -aALL
#Stop blinking
megacli -PdLocate -stop  -physdrv\[4:1\]  -aALL
megacli -PdLocate -stop  -physdrv\[4:2\]  -aALL
megacli -PdLocate -stop  -physdrv\[4:3\]  -aALL
 
# Проверка состояния BBU (Battery Backup Unit)
megacli -adpbbucmd -aall
# Посмотреть прогресс добавления диска в RAID
megacli -pdrbld -showprog -physdrv[4:0] -aAll

Мониторинг дисков используя smartctl

Для этого нам понадобиться тот же megacli, используя который, мы узнаем ID физических дисков и соответствующие им логические носители. Начнем.
Узнаем ID всех физических дисков за мегарейд контроллером ну и номера соответствующих логических дисков.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
root@il-nv-s06:~# megacli -LdPdInfo -aALL | grep Id
Virtual Drive: 0 (Target Id: 0)
Device Id: 0
Device Id: 1
Device Id: 2
Device Id: 3
Virtual Drive: 1 (Target Id: 1)
Device Id: 13
Device Id: 12
Virtual Drive: 2 (Target Id: 2)
Device Id: 11
Device Id: 10
Device Id: 9
Device Id: 6
Device Id: 7
Device Id: 8
Расшифрую эту команду:
  • -LdPdInfo — получить информацию(Info) по логическим (Ld) и физическим(Pd) устройствам …
  • -aALL — … на всех адаптерах
Теперь видно, что у нас три логических(виртуальных) диска в которые входят по несколько физических дисков с соответствующими ID. Посмотрим на сервере, сколько у нас есть дисков:
1
2
root@il-nv-s06:~# ls /dev/sd[a-Z]
/dev/sda  /dev/sdb  /dev/sdc
Все верно, у нас три логических диска в системе. Проводим аналогию с выводом команды megacli:
  • Virtual Drive: 0 == /dev/sda и в него входит 4 физических диска с ID=0,1,2,3
  • Virtual Drive: 1 == /dev/sdb и в него входит 2 физических диска с ID=13,12
  • Virtual Drive: 2 == /dev/sdc и в него входит 6 физических дисков с ID=6,7,8,9,10,11
Теперь нам осталось запустить SMART проверку по каждому с дисков используя собранные данные.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
root@il-nv-s06:~# cat smartcheck.sh
#!/bin/bash
echo "============================================="
echo "================== /dev/sda ================="
echo "============================================="
smartctl -d megaraid,0 -a /dev/sda
smartctl -d megaraid,1 -a /dev/sda
smartctl -d megaraid,2 -a /dev/sda
smartctl -d megaraid,3 -a /dev/sda
echo "============================================="
echo "================== /dev/sdb ================="
echo "============================================="
smartctl -d megaraid,13 -a /dev/sdb
smartctl -d megaraid,12 -a /dev/sdb
echo "============================================="
echo "================== /dev/sdc ================="
echo "============================================="
smartctl -d megaraid,11 -a /dev/sdc
smartctl -d megaraid,10 -a /dev/sdc
smartctl -d megaraid,9 -a /dev/sdc
smartctl -d megaraid,6 -a /dev/sdc
smartctl -d megaraid,7 -a /dev/sdc
smartctl -d megaraid,8 -a /dev/sdc
К примеру возьмем первый диск.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
root@il-nv-s06:~# smartctl -d megaraid,0 -a /dev/sda
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.8.0-26-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
 
Vendor:               SEAGATE
Product:              ST31000424SS
Revision:             0005
User Capacity:        1,000,204,886,016 bytes [1.00 TB]
Logical block size:   512 bytes
Logical Unit id:      0x5000c5002130cd0b
Serial number:        9WK1D0420000C1051TRW
Device type:          disk
Transport protocol:   SAS
Local Time is:        Fri Feb  7 20:24:25 2014 IST
Device supports SMART and is Enabled
Temperature Warning Enabled
SMART Health Status: OK
 
Current Drive Temperature:     29 C
Drive Trip Temperature:        68 C
Manufactured in week 32 of year 2010
Specified cycle count over device lifetime:  10000
Accumulated start-stop cycles:  30
Specified load-unload count over device lifetime:  300000
Accumulated load-unload cycles:  2
Elements in grown defect list: 0
Vendor (Seagate) cache information
  Blocks sent to initiator = 920579338
  Blocks received from initiator = 3734205770
  Blocks read from cache and sent to initiator = 2669309657
  Number of read and write commands whose size <= segment size = 101596876   Number of read and write commands whose size > segment size = 1211
Vendor (Seagate/Hitachi) factory information
  number of hours powered up = 24230.63
  number of minutes until next internal SMART test = 20
 
Error counter log:
           Errors Corrected by           Total      Correction         Gigabytes         Total
               ECC          rereads/    errors       algorithm         processed   uncorrected
           fast | delayed   rewrites  corrected    invocations      [10^9 bytes]        errors
read:   3033913199      210         0  3033913409   3033913469      39052.656          60
write:           0        0         0          0             0       4141.743           0
verify:   75533051       10         0    75533061     75533061       1001.100           0
 
Non-medium error count:       14
 
[GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on']
 
SMART Self-test log
Num  Test              Status                 segment  LifeTime  LBA_first_err [SK ASC ASQ]
     Description                              number   (hours)
# 1  Background long   Completed                   -   24200                 - [-   -    -]
 
Long (extended) Self Test duration: 11100 seconds [185.0 minutes]
Как видим у нас есть 60 ошибок с которыми не смогла справиться система исправления ошибок.
Немного расшифрую выводу ошибок:
Журнал ошибок (если он доступен) отображается в отдельных строках:
  • write error counters — ошибки записи
  • read error counters — ошибки считывания
  • verify error counters (отображаются только когда не нулевое значение) — ошибки выполнения
  • non-medium error counter (определенное число) — число восстанавливаемых ошибок отличных от ошибок записи/считывания/выполнения
Так же может выводиться детальное описание последних ошибок с кодом, если устройство его поддерживает(если нет поддержки — выводиться сообщение «Error Events logging not supported»). К примеру:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Error 3 occurred at disk power-on lifetime: 23855 hours (993 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 08 4c 08 0f e0  Error: IDNF at LBA = 0x000f084c = 985164
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ca 00 08 4c 08 0f 00 08  19d+06:08:39.873  WRITE DMA
  ca 00 08 5c 05 0f 00 08  19d+06:08:39.873  WRITE DMA
  c8 00 10 9c a0 25 00 08  19d+06:08:39.866  READ DMA
  c8 00 08 94 a0 25 00 08  19d+06:08:39.866  READ DMA
  c8 00 08 8c a0 25 00 08  19d+06:08:39.862  READ DMA
Каждая из ошибок имеет различные коды. Оригинал описания кодов взято из мануала по SCSI Seagate дискам:
Errors Corrected by ECC, fast [Errors corrected without substantial delay: 00h]. An error correction was applied to get perfect data (a.k.a. ECC on-the-fly). «Without substantial delay» means the correction did not postpone reading of later sectors (e.g. a revolution was not lost). The counter is incremented once for each logical block that requires correction. Two different blocks corrected during the same command are counted as two events.
Errors Corrected by ECC: delayed [Errors corrected with possible delays: 01h]. An error code or algorithm (e.g. ECC, checksum) is applied in order to get perfect data with substantial delay. «With possible delay» means the correction took longer than a sector time so that reading/writing of subsequent sectors was delayed (e.g. a lost revolution). The counter is incremented once for each logical block that requires correction. A block with a double error that is correctable counts as one event and two different blocks corrected during the same command count as two events.
Error corrected by rereads/rewrites [Total (e.g. rewrites and rereads): 02h]. This parameter code specifies the counter counting the number of errors that are corrected by applying retries. This counts errors recovered, not the number of retries. If five retries were required to recover one block of data, the counter increments by one, not five. The counter is incremented once for each logical block that is recovered using retries. If an error is not recoverable while applying retries and is recovered by ECC, it isn’t counted by this counter; it will be counted by the counter specified by parameter code 01h — Errors Corrected With Possible Delays.
Total errors corrected [Total errors corrected: 03h]. This counter counts the total of parameter code errors 00h, 01h and 02h (i.e. error corrected by ECC: fast and delayed plus errors corrected by rereads and rewrites). There is no «double counting» of data errors among these three counters. The sum of all correctable errors can be reached by adding parameter code 01h and 02h errors, not by using this total. [The author does not understand the previous sentence from the Seagate manual.]
Correction algorithm invocations [Total times correction algorithm processed: 04h]. This parameter code specifies the counter that counts the total number of retries, or «times the retry algorithm is invoked». If after five attempts a counter 02h type error is recovered, then five is added to this counter. If three retries are required to get stable ECC syndrome before a counter 01h type error is corrected, then those three retries are also counted here. The number of retries applied to unsuccessfully recover an error (counter 06h type error) are also counted by this counter.
Gigabytes processed {10^9} [Total bytes processed: 05h]. This parameter code specifies the counter that counts the total number of bytes either successfully or unsuccessfully read, written or verified (depending on the log page) from the drive. If a transfer terminates early because of an unrecoverable error, only the logical blocks up to and including the one with the uncorrected data are counted. [smartmontools divides this counter by 10^9 before displaying it with three digits to the right of the decimal point. This makes this 64 bit counter easier to read.]
Total uncorrected errors [Total uncorrected errors: 06h]. This parameter code specifies the counter that contains the total number of blocks for which an uncorrected data error has occurred.
С всего этого нас интересует параметр Total uncorrected errors который показывает количество не исправленных ошибок. Если это число велико, то нужно запускать long тест и проверить, дополнительно, параметры физического диска в Megaraid контроллере.

Мониторинг дисков используя smartd

Предыдущие способы мониторинга дисков были ручными, т.е. нужно вручную запускать проверку дисков находясь на конкретном сервере, или же настроить систему мониторинга, которая будет использовать написанные выше скрипты для сбора информации о состоянии дисков. Но есть еще один способ мониторинга — это использование демона smartd, который будет отправлять нам письма о проблемных дисках. Детально о настройках демона smartd можно почитать здесь
Для начала добавим демон в автозагрузку.
1
2
3
root@il-nv-s06:~# cat /etc/default/smartmontools
start_smartd=yes
smartd_opts="--interval=3600"
Так же было добавлено интервал запуска проверок. Далее нам нужно добавить диски на мониторинг, для чего служит файл smartd.conf.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
root@il-nv-s06:~# cat /etc/smartd.conf
#Диски, которые нужно мониторить
/dev/sda -d megaraid,0 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sda -d megaraid,1 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sda -d megaraid,2 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sda -d megaraid,3 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdb -d megaraid,13 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdb -d megaraid,12 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdc -d megaraid,11 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdc -d megaraid,10 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdc -d megaraid,9 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdc -d megaraid,6 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdc -d megaraid,7 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
/dev/sdc -d megaraid,8 -o on -S on -m your@emailaddress.com -M diminishing -a -s (S/../.././00|L/../../7/03)
root@il-nv-s06:~# /etc/init.d/smartd restart
Немного расшифрую вывод. Для все дисков включено запуск офлайн тестов (-o on) для обновление и сохранения значений атрибутов (-S on). Так же добавлена проверка всех текущих параметров (-а) и назначено запуск дополнительных коротких тестов каждый день в полночь (S/../.././00) и долгих тестов каждое воскресенье с 3 часов ночи (L/../../7/03). Если будет проблема хотя бы с одной из метрик — будет отправлено письмо на соответствующий адрес (-m your@emailaddress.com). При этом письма будут отправляться систематически — 1,2,4,8,16,… дни (-M diminishing), пока проблема не будет устранена.
В следующей статье я постараюсь описать решение проблемы с батареей Megaraid та и любого другого RAID-контролера. Потом поговорим о мониторинге дисков под HP контроллером (HP/Compaq SmartArray)

Мониторинг BBU RAID контроллеров

В предыдущей статье шла речь об установки megacli для мониторинга дисков под LSI 2108 Megaraid контроллеров. Сейчас же я хочу немного описать мониторинг батареи (BBU) для RAID контроллеров в целом. Какие шаги нужно предпринимать и как не наделать лишних проблем для себя при возникновении ошибок или неполадок с BBU (Battery Backup Unit).
Состояние батареи нужно периодически проверять. Для RAID контроллеров этот компонент вообще может отсутствовать, так как его основное предназначение — это держать в кэше данные, которые еще не записались на диск, т.е. сохранение целостности данных при сбое питания (внезапное отключения подачи электричества).
На данный момент, почти все рейд контроллеры поддерживают кэширование данных на уровне контроллера. Т.е. каждый физический диск имеет свой кэш плюс кэш контроллера. Такой подход повышает производительность системы при сохранение большого количества данных или же при очень высоком уровне отдачи контента конечным пользователям.
Если рейд контроллер умеет кэшировать данные, то на нем можно настроить политику считывания, записи и буферизации данных.

Read Policy: Политика считывания указывает каким образом контроллеру нужно считывать сектора логических устройств при поиске нужной информации.
  • Read-Ahead. Когда используется политика упреждающего (на перед) чтение, контроллер включает режим последовательного считывания секторов с логических дисков при поиске данных. Производительность повышается, если данных записаны последовательно, сектор за сектором на логические диски.
  • No-Read-Ahead. Режим отключения политика последовательного считывания данных на контроллере.
  • Adaptive Read-Ahead. Когда включена адаптивная политика упреждающего чтение, контроллер инициализирует упреждающее чтение только если пришел запрос на очень часто считываемые данные, которые записаны последовательно на логический диск. Если же запрашиваются рендомные(записанные в случайной последовательности) данные — контроллер переходит в режим no-read-ahead.
Про политику записи и буферизации лучше читать в оригинале.
Write Policy: The write policies specify whether the controller sends a write-request completion signal as soon as the data is in the cache or after it has been written to disk.
  • Write-Back. When using write-back caching, the controller sends a write-request completion signal as soon as the data is in the controller cache but has not yet been written to disk. Write-back caching may provide improved performance since subsequent read requests can more quickly retrieve data from the controller cache than they could from the disk. Write-back caching also entails a data security risk, however, since a system failure could prevent the data from being written to disk even though the controller has sent a write-request completion signal. In this case, data may be lost. Other applications may also experience problems when taking actions that assume the data is available on the disk.
В этом режиме как только данные попали в кэш — контроллер говорит, что данные уже сохранены. Это повышает производительность но ставит под угрозу целостность данных.
  • Write-Through. When using write-through caching, the controller sends a write-request completion signal only after the data is written to the disk. Write-through caching provides better data security than write-back caching, since the system assumes the data is available only after it has been safely written to the disk.
В этом режиме данные попадать в кэш, записываются на дик и только тогда контроллер отвечает, что данные сохранены. Это повышает целостность данных, но уменьшает производительность.
Cache Policy: The Direct I/O and Cache I/O cache policies apply to reads on a specific virtual disk. These settings do not affect the read-ahead policy. The cache policies are as follows:
  • Cache I/O. Specifies that all reads are buffered in cache memory.
Все считанные данные буферизируются в кэше.
  • Direct I/O. Specifies that reads are not buffered in cache memory. When using direct I/O, data is transferred to the controller cache and the host system simultaneously during a read request. If a subsequent read request requires data from the same data block, it can be read directly from the controller cache. The direct I/O setting does not override the cache policy settings. Direct I/O is also the default setting.
Данные не буферизируются в кэше.
Теперь перейдем к практике на примере мегарейд контроллера.
Для начала нужно проверить логи:
1
root@il:~# megacli -fwtermlog -dsply -aall
Если вывелась куча строк типа:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
02/13/14  6:30:57: EVT#715494-02/13/14  6:30:57: 150=Battery needs replacement - SOH Bad
02/13/14  6:32:02: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:32:02: Battery needs replacement
02/13/14  6:32:02: EVT#715495-02/13/14  6:32:02: 150=Battery needs replacement - SOH Bad
02/13/14  6:33:07: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:33:07: Battery needs replacement
02/13/14  6:33:07: EVT#715496-02/13/14  6:33:07: 150=Battery needs replacement - SOH Bad
02/13/14  6:34:12: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:34:12: Battery needs replacement
02/13/14  6:34:12: EVT#715497-02/13/14  6:34:12: 150=Battery needs replacement - SOH Bad
02/13/14  6:35:17: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:35:17: Battery needs replacement
02/13/14  6:35:17: EVT#715498-02/13/14  6:35:17: 150=Battery needs replacement - SOH Bad
02/13/14  6:36:22: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:36:22: Battery needs replacement
02/13/14  6:36:22: EVT#715499-02/13/14  6:36:22: 150=Battery needs replacement - SOH Bad
02/13/14  6:37:27: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:37:27: Battery needs replacement
02/13/14  6:37:27: EVT#715500-02/13/14  6:37:27: 150=Battery needs replacement - SOH Bad
02/13/14  6:38:32: Not enough charge capacity left in battery for expeded data retention duration
02/13/14  6:38:32: Battery needs replacement
02/13/14  6:38:32: EVT#715501-02/13/14  6:38:32: 150=Battery needs replacement - SOH Bad
02/13/14  6:39:37: Not enough charge capacity left in battery for expeded data retention duration
… первым делом проверяем статус BBU установленной тулзой:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
root@il:~# megacli -adpbbucmd -aall
 
BBU status for Adapter: 0
 
BatteryType: iBBU
Voltage: 4008 mV
Current: 0 mA
Temperature: 26 C
Battery State: Failed
BBU Firmware Status:
 
  Charging Status              : None
  Voltage                                 : OK
  Temperature                             : OK
  Learn Cycle Requested                   : No
  Learn Cycle Active                      : No
  Learn Cycle Status                      : OK
  Learn Cycle Timeout                     : No
  I2c Errors Detected                     : No
  Battery Pack Missing                    : No
  Battery Replacement required            : Yes
  Remaining Capacity Low                  : Yes
  Periodic Learn Required                 : No
  Transparent Learn                       : No
  No space to cache offload               : No
  Pack is about to fail & should be replaced : No
  Cache Offload premium feature required  : No
  Module microcode update required        : No
 
GasGuageStatus:
  Fully Discharged        : No
  Fully Charged           : Yes
  Discharging             : Yes
  Initialized             : Yes
  Remaining Time Alarm    : No
  Discharge Terminated    : No
  Over Temperature        : No
  Charging Terminated     : No
  Over Charged            : No
  Relative State of Charge: 96 %
  Charger System State: 49168
  Charger System Ctrl: 0
  Charging current: 0 mA
  Absolute state of charge: 5161 %
  Max Error: 19 %
  Battery backup charge time : 0 hours
 
BBU Capacity Info for Adapter: 0
 
  Relative State of Charge: 96 %
  Absolute State of charge: 5161 %
  Remaining Capacity: 62706 mAh
  Full Charge Capacity: 65467 mAh
  Run time to empty: Battery is not being charged.
  Average time to empty: Battery is not being charged.
  Estimated Time to full recharge: Battery is not being charged.
  Cycle Count: 119
Max Error = 19 %
Remaining Capacity Alarm = 120 mAh
Remining Time Alarm = 10 Min
 
BBU Design Info for Adapter: 0
 
  Date of Manufacture: 12/01, 2010
  Design Capacity: 1215 mAh
  Design Voltage: 3700 mV
  Specification Info: 33
  Serial Number: 3241
  Pack Stat Configuration: 0x64a0
  Manufacture Name: LS1121001A
  Firmware Version   :
  Device Name: 3150301
  Device Chemistry: LION
  Battery FRU: N/A
  Transparent Learn = 0
  App Data = 0
 
BBU Properties for Adapter: 0
 
  Auto Learn Period: 30 Days
  Next Learn time: Thu Feb 20 06:33:27 2014
  Learn Delay Interval:0 Hours
  Auto-Learn Mode: Enabled
Убеждаемся, что проблема есть по параметрам — Battery Replacement required : Yes и Battery State: Failed. Перед паникой и заменой, нужно дополнительно посмотреть параметр Run time to empty: Battery is not being charged. — Это означает, что нужно ее зарядить, так как она еще ни разу не заряжалась и состояние заряда :
Relative State of Charge: 96 %
Absolute State of charge: 5161 %
Значит первым делом нужно попробовать зарядить BBU и если не помогло — проверить все ли правильно подсоединено. Если проблема не решилась — нужно проводить замену.
Можно пользоваться этими шагами для определения и решения проблемы с BBU:
Num Type Description Indication Actions
2 F Unable to recover cache data from TBBU A,B 1
10 F Controller cache discarded due to memory/battery problems A,B 1
11 F Unable to recover cache data due to configuration mismatch A,B,C 1
146 W Battery voltage low N/A 1,2
162 W Current capacity of the battery is below threshold B 1,2
150 F Battery needs replacement — SOH Bad D 1,2
154 W Battery relearn timed out D 1,2
161 W Battery removed D 1,2
200 C Battery/charger problems detected: SOH Bad D 1,2
211 C BBU Retention test failed! G 1,2
142 W Battery Not Present N/A 1,2
253 W Battery requires reconditioning: please initiate a LEARN cycle N/A 3
307 W Periodic Battery Relearn is pending. Please initiate manual leam cycle as Automatic leam is not enabled H 3
195 W BBU disabled: changing WB to WT E, F 4,5
330 W Detected error with the remote battery connector cable N/A 6
Type:
F= Fatal. W=Warning. C=Critical.
Indication:
A) Sudden power loss or system hang, when BBU is not fully charged and Write Back mode is forcefully enabled
B) The extended power loss to the system has resulted in the BBU being thoroughly discharged before power recovery.
C) The specific virtual drive configuration may have changed, so that previous virtual drive information cannot be recovered from BBU data
D) BBU failure or it is installed or connected incorrectly.
E) BBU not connected or not fully charged.
F) If WB mode was enabled before BBU charge, then it will be automatically re-enabled after the charge
G) BBU not able to keep cache data long enough during system power off.
H) The battery requires a relearn cycle to re-calibrate itself.
Action
1) Check the BBU status to see if the BBU should be charged or replaced.
2) Check the cable, power connection, backplane, SATA/SAS port, and make sure the BBU is installed and connected correctly.
3) Use RAID Web Console 2 or RAID BIOS Console to initiate a battery re-learn cycle.
4) Wait until the BBU is fully charged before rebooting the system.
5) WB can still be used through Bad BBU mode under RAID Web Console 2 but unexpected
power failure may cause data loss.
6) Check if the remote battery connector cable is properly connected and functional.

Комментариев нет: